Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

618-11 Burial Ground USRADS radiological surveys

Technical Report ·
DOI:https://doi.org/10.2172/10161361· OSTI ID:10161361
This report summarizes and documents the results of the radiological surveys conducted from February 4 through February 10, 1993 over the 618-11 Burial Ground, Hanford Site, Richland, Washington. In addition, this report explains the survey methodology using the Ultrasonic Ranging and Data System (USRADS). The 618-11 Burial Ground radiological survey field task consisted of two activities: characterization of the specific background conditions and the radiological survey of the area. The radiological survey of the 618-11 Burial Ground, along with the background study, were conducted by Site Investigative Surveys Environmental Restoration Health Physics Organization of the Westinghouse Hanford Company. The survey methodology was based on utilization of the Ultrasonic Ranging and Data System (USRADS) for automated recording of the gross gamma radiation levels at or near six (6) inches and at three (3) feet from the surface soil.