Title: High Pressure Coolant Injection system risk-based inspection guide for Hatch Nuclear Power Station

Technical Report ·
OSTI ID:10159297
 [1]
  1. Brookhaven National Lab., Upton, NY (United States)

A review of the operating experience for the High Pressure Coolant Injection (HPCI) system at the Hatch Nuclear Power Station, Units 1 and 2, is described in this report. The information for this review was obtained from Hatch Licensee Event Reports (LERs) that were generated between 1980 and 1992. These LERs have been categorized into 23 failure modes that have been prioritized based on probabilistic risk assessment considerations. In addition, the results of the Hatch operating experience review have been compared with the results of a similar, industry wide operating, experience review. This comparison provides an indication of areas in the Hatch HPCI system that should be given increased attention in the prioritization of inspection resources.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Systems Safety and Analysis; Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
10159297
Report Number(s):
NUREG/CR-6014; BNL-NUREG-52367; ON: TI93014063; TRN: 93:020840
Resource Relation:
Other Information: PBD: May 1993
Country of Publication:
United States
Language:
English