Title: Performance of a 30-kV, 1-kHz, nanosecond source

Conference ·
OSTI ID:10158995

An existing pulser at LLNL was modified to increase its repetition rate to 1000 Hz. Spark gap recovery measurements were made for both the Marx and the Blumlein output switches. Recovery times of less than 1 ms were recorded without gas flow in the switch chambers. Low pressure synthetic air was used as the switch dielectric. Longer recovery times were necessary to over-voltage the switch. The output of the pulser was used to drive a log-periodic-dipole-array. Measurements were made on the transmitted pulses in an anechoic chamber and yielded a center frequency of 80 MHz. This paper describes the modifications made on the pulse generator, discusses the spark gap recovery data, and summarizes the performance of the pulser at 1 kHz. In addition, a brief description of the antenna is given along with the field measurements that were made in the EMPEROR facility.

Research Organization:
Lawrence Livermore National Lab., CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
10158995
Report Number(s):
UCRL-JC-110978; CONF-920671-15; ON: DE93012607
Resource Relation:
Conference: 20. international power modulator symposium,Myrtle Beach, SC (United States),23-25 Jun 1992; Other Information: PBD: Jun 1992
Country of Publication:
United States
Language:
English

Similar Records

Performance of a 30-kV, 1-kHz, nanosecond source
Conference · Mon Jun 01 00:00:00 EDT 1992 · OSTI ID:10158995

Development of a repetitive 1-MV, 22-kJ Marx generator
Conference · Thu Jan 01 00:00:00 EST 1987 · OSTI ID:10158995

Bipolar high-repetition-rate high-voltage nanosecond pulser
Journal Article · Sun Jun 15 00:00:00 EDT 2008 · Review of Scientific Instruments · OSTI ID:10158995