Major device parameters for ITER-EDA and CDA are given in this paper. Ignition capability of the EDA (and CDA) operational scenarios is evaluated using both the 1-1/2-D time-dependent transport simulations and 0-D global models under different confinement [{chi}({triangledown}T{sub e}){sub crit}, empirical global energy confinement scalings, {chi}(empirical), etc.] assumptions. Results from some of these transport simulations and confinement assessments are summarized in and compared with the ITER CDA reference ignition scenario.