Flux distributions with typical rod and loading patterns

Technical Report ·
DOI:https://doi.org/10.2172/10155400· OSTI ID:10155400
Side-to-side flux distributions calculated for ``rods out`` operation are compared to the normal equilibrium distributions. The results are highly sensitive to enrichment and flattening unbalance. Near side tube power limits are reached at total pile powers as low as 39%, and as high as 85% of the normal equilibrium. power. Calculations indicate that, with the current loading patterns, B, D, DR, F, H, and KW, theoretically could make rods out scram recoveries without exceeding tube power limits, whereas C and KE could not. Longitudinal flux profiles corresponding to possible control rod and mixing piece configurations are compared to the ideal cosine distribution. Peak fluxes for a given column power vary from 86 to 111 % of a cosine maximum. The position of the maximum flux varies from 115 cm (5.1 slugs) downstream to 131 cm (5.8 slugs) upstream of the center line of the slug column. The effects of non-uniform (front-to-rear) enrichment and flattening charges are not considered.
Research Organization:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
10155400
Report Number(s):
HW--61752; ON: DE94012881
Country of Publication:
United States
Language:
English

Similar Records

Axial power profiles in SRP reactors during LOCA
Technical Report · Fri Jun 26 00:00:00 EDT 1987 · OSTI ID:6953543

Slug and tube factors
Technical Report · Thu May 13 00:00:00 EDT 1954 · OSTI ID:6491961

Use of a programmable desk calculator to achieve fast, accurate control rod calibration
Conference · Fri Dec 31 23:00:00 EST 1971 · OSTI ID:4394203