BNCP prototype detonator studies using a semiconductor bridge initiator
Conference
·
OSTI ID:10155017
- Pacific Scientific Co., Avondale-Goodyear, AZ (United States). Energy Dynamics Div.
- Sandia National Labs., Albuquerque, NM (United States)
We report on experiments with prototype BNCP detonators incorporating a semiconductor bridge, SCB. We tested two device designs; one for DoD and one for DOE applications. We report tests with the DoD detonator using different firing conditions and two different grain sizes of BNCP. The DOE detonator utilized a 50 {mu}F CDU firing set with a 24 V all-fire condition.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 10155017
- Report Number(s):
- SAND--94-0336C; CONF-940776--2; ON: DE94012725; BR: GB0103012
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterization and electrical modeling of semiconductors bridges
Electrical modeling of semiconductor bridge (SCB) BNCP detonators with electrochemical capacitor firing sets
Smart semiconductor bridge (SCB) igniter for explosives
Technical Report
·
Fri Feb 28 23:00:00 EST 1997
·
OSTI ID:481914
Electrical modeling of semiconductor bridge (SCB) BNCP detonators with electrochemical capacitor firing sets
Technical Report
·
Sat Oct 31 23:00:00 EST 1998
·
OSTI ID:665850
Smart semiconductor bridge (SCB) igniter for explosives
Conference
·
Thu Dec 31 23:00:00 EST 1987
·
OSTI ID:6841533