Transient evolution of the power radiated coherently by a charged- particle bunch orbiting between two infinite, parallel conducting plates is calculated. The plates comprise an idealized vacuum pipe in a bending magnet. The bunch moves on a trajectory such that it suddenly diverts from a straight-line path to a circular orbit and begins radiating. The influence of the plates on the transients is contrasted to their shielding of the steady-state radiated power. The effect of the radiation field on beam emittance in a magnetic bending system is also quantified. 18 refs., 1 fig.
Research Organization:
Southeastern Universities Research Association, Inc., Newport News, VA (United States). Continuous Electron Beam Accelerator Facility
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
10154968
Report Number(s):
DOE/ER/40150--369; CEBAF-PR--96-012; ON: DE96006257
Country of Publication:
United States
Language:
English