Action plan for response to abnormal conditions in Hanford high level radioactive liquid waste storage tanks containing flammable gases. Revision 1
Radioactive liquid waste tends to produce hydrogen as a result of the interaction of gamma radiation and water. In tanks containing organic chelating agents, additional hydrogen gas as well as nitrous oxide and ammonia can be produced by thermal and radiolytic decomposition of these organics. Several high-level radioactive liquid waste storage tanks, located underground at the Hanford Site, contain waste that retains the gases produced in them until large quantities are released rapidly to the tank vapor space. Tanks filled to near capacity have relatively little vapor space; therefore, if the waste suddenly releases a large amount of hydrogen and nitrous oxide, a flammable gas mixture may result. The most notable waste tank with a flammable gas problem is tank 241-SY-101. Waste in this tank has occasionally released enough flammable gas to burn if an ignition source had been present inside of the tank. Several other waste tanks exhibit similar behavior to a lesser magnitude. Administrative controls have been developed to assure that these Flammable Gas Watch List tanks are safely maintained. Responses have also been developed for off-normal conditions which might develop in these tanks. In addition, scientific and engineering studies are underway to further understand and mitigate the behavior of the Flammable Gas Watch List tanks.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10149511
- Report Number(s):
- WHC-EP--0436-Rev.1; ON: DE94011394; BR: 35AF11201/35AF11202
- Country of Publication:
- United States
- Language:
- English
Similar Records
A summary description of the flammable gas tank safety program
Flammable gas tank safety program: Technical basis for gas analysis and monitoring
Hydrogen mitigation Gas Characterization System: System design description
Technical Report
·
Sat Oct 01 00:00:00 EDT 1994
·
OSTI ID:10191651
Flammable gas tank safety program: Technical basis for gas analysis and monitoring
Technical Report
·
Fri Sep 08 00:00:00 EDT 1995
·
OSTI ID:274194
Hydrogen mitigation Gas Characterization System: System design description
Technical Report
·
Fri Jul 17 00:00:00 EDT 1998
·
OSTI ID:344969