Evaluation of copper for divider subassembly in MCO Mark IA and Mark IV scrap fuel baskets
The K Basin Spent Nuclear Fuel (SNF) Project Multi-Canister Overpack (MCO) subprojection eludes the design and fabrication of a canister that will be used to confine, contain, and maintain fuel in a critically safe array to enable its removal from the K Basins, vacuum drying, transport, staging, hot conditioning, and interim storage (Goldinann 1997). Each MCO consists of a shell, shield plug, fuel baskets (Mark IA or Mark IV), and other incidental equipment. The Mark IA intact and scrap fuel baskets are a safety class item for criticality control and components necessary for criticality control will be constructed from 304L stainless steel. It is proposed that a copper divider subassembly be used in both Mark IA and Mark IV scrap baskets to increase the safety basis margin during cold vacuum drying. The use of copper would increase the heat conducted away from hot areas in the baskets out to the wall of the MCO by both radiative and conductive heat transfer means. Thus copper subassembly will likely be a safety significant component of the scrap fuel baskets. This report examines the structural, cost and corrosion consequences associated with using a copper subassembly in the stainless steel MCO scrap fuel baskets.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 10147979
- Report Number(s):
- HNF-SD-SNF-ER-019; ON: DE99050271; BR: EW7040000; TRN: AHC29927%%15
- Resource Relation:
- Other Information: PBD: 29 Sep 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Use of fixed neutron absorbers by the Hanford spent nuclear fuel project
Criticality safety evaluation report for the multi-canister overpack