Tuning the narrow-band beam position monitor sampling clock to remove the aliasing errors in APS storage ring orbit measurements.
- Accelerator Systems Division (APS)
The Advanced Photon Source storage ring employs a real-time orbit correction system to reduce orbit motion up to 50 Hz. This system uses up to 142 narrow-band rf beam position monitors (Nbbpms) in a correction algorithm by sampling at a frequency of 1.53 kHz. Several Nbbpms exhibit aliasing errors in orbit measurements, rendering these Nbbpms unusable in real-time orbit feedback. The aliasing errors are caused by beating effects of the internal sampling clocks with various other processing clocks residing within the BPM electronics. A programmable external clock has been employed to move the aliasing errors out of the active frequency band of the real-time feedback system (RTFB) and rms beam motion calculation. This paper discusses the process of tuning and provides test results.
- Research Organization:
- Argonne National Laboratory (ANL)
- Sponsoring Organization:
- SC
- DOE Contract Number:
- AC02-06CH11357
- OSTI ID:
- 1014787
- Report Number(s):
- ANL/ASD/CP-59537
- Country of Publication:
- United States
- Language:
- ENGLISH
Similar Records
Commissioning results of the narrow-band beam position monitor system upgrade in the APS storage ring.
Aliasing errors in measurements of beam position and ellipticity
Dynamic X-Y Crosstalk / Aliasing Errors of Multiplexing BPMs
Conference
·
Tue Apr 20 00:00:00 EDT 1999
·
OSTI ID:11144
Aliasing errors in measurements of beam position and ellipticity
Journal Article
·
Thu Sep 15 00:00:00 EDT 2005
· Review of Scientific Instruments
·
OSTI ID:20723149
Dynamic X-Y Crosstalk / Aliasing Errors of Multiplexing BPMs
Conference
·
Tue Aug 09 00:00:00 EDT 2005
·
OSTI ID:878800