Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiochemistry for the rupture of Zircaloy-2 clad heavy-walled tubular fuel element in KER Loop-3

Technical Report ·
DOI:https://doi.org/10.2172/10145420· OSTI ID:10145420

On the 0000 -- 0800 shift, December 9, 1960, the delayed neutron monitor on KER Loop 3 gave a high coolant activity signal indicating a possible fuel element failure in this loop. KE Reactor was shut down immediately thereafter. This report is being written to summarize the events pertinent to this KE Reactor scram and to discuss the results and significance of data from analyses on coolant and coupon samples taken from the KER Loop 3 system.

Research Organization:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
10145420
Report Number(s):
HW--70807; ON: DE94010619
Country of Publication:
United States
Language: