Progress toward resolution of vapor problems associated with tank 241-C-103

Conference ·
OSTI ID:10144087
;  [1];  [2]
  1. Westinghouse Hanford Co., Richland, WA (United States)
  2. Northwest Instrument Systems, Inc. (United States)
Noxious and flammable gases and vapors associated with high-level radioactive waste storage tank 241-C-103 at the Hanford Site are discussed. Focus is on the Westinghouse Hanford Company strategy to characterize the tank headspace. The sampling and analysis methodology is described. Sampling limitations, devices, and equipment are discussed. Results to date are given.