Assessment of diagnostic methods for determining degradation of motor-operated valves
Conference
·
OSTI ID:10138571
- Oak Ridge National Lab., TN (United States)
- Nuclear Regulatory Commission, Rockville, MD (United States)
The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of motor-operated valves (MOVs) in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL MOV aging assessment with emphasis on the identification, evaluation, and application of MOV monitoring methods and techniques. The diagnostic information available from any MOV measurable parameters was evaluated by ORNL using MOVs that were mounted on test stands. Those tests led to the conclusion that the single most informative MOV measurable parameter was also the one which was most easily acquired, namely the motor current. Motor current signature analysis (MCSA) was found to provide detailed information related to the condition of the motor, motor operator, and valve across a wide range of levels. As part of the MOV aging assessment, several tests were carried out by ORNL on MOVs having implanted defects and degradations. Tests were also performed on many MOVs located within a nuclear power plant. In addition, ORNL participated in the Gate Valve Flow Interruption Blowdown Test program carried out at Wyle Laboratories in Huntsville, Alabama. Results from all of these tests are summarized in this paper and several selected examples are given. Other areas covered in this paper include descriptions of relevant regulatory issues and activities, other related diagnostics research at ORNL, and interactions ORNL has had with outside organizations for the purpose of disseminating research results.
- Research Organization:
- Oak Ridge National Lab., TN (United States)
- Sponsoring Organization:
- Nuclear Regulatory Commission, Washington, DC (United States)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 10138571
- Report Number(s):
- CONF-920375--11; ON: DE92011078
- Country of Publication:
- United States
- Language:
- English
Similar Records
Assessment of diagnostic methods for determining degradation of motor-operated valves
Aging and service wear of electric motor-operated valves used in engineered safety-feature systems of nuclear power plants: Aging assessments and monitoring method evaluations
Application of signature analysis for determining the operational readiness of motor-operated valves under blowdown test conditions
Conference
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:5374369
Aging and service wear of electric motor-operated valves used in engineered safety-feature systems of nuclear power plants: Aging assessments and monitoring method evaluations
Technical Report
·
Tue Aug 01 00:00:00 EDT 1989
·
OSTI ID:5684053
Application of signature analysis for determining the operational readiness of motor-operated valves under blowdown test conditions
Conference
·
Thu Dec 31 23:00:00 EST 1987
·
OSTI ID:6953570