At the request of the Waste Disposal Technology Division of Savannah River Plants the Chemical Technology Division is investigating vitrification of alpha waste incinerator (AWI) ash. This memorandum describes tests carried out to determine the corrosion rate of Monofrax K-3{reg_sign} and Inconel 690{reg_sign} at 1150{degrees}C in Frit 131 containing up to 50 wt % ash.
Research Organization:
Du Pont de Nemours (E.I.) and Co., Aiken, SC (United States). Savannah River Lab.
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035; AC09-76SR00001
OSTI ID:
10138273
Report Number(s):
DPST--82-648; ON: DE92010677