Development and evaluation of a cleanable high efficiency steel filter
- Lawrence Livermore National Lab., CA (United States)
- Martin Marietta Energy Systems, Inc., Oak Ridge, TN (United States)
We have developed a high efficiency steel filter that can be cleaned in-situ by reverse air pulses. The filter consists of 64 pleated cylindrical filter elements packaged into a 6l0 {times} 6l0 {times} 292 mm aluminum frame and has 13.5 m{sup 2} of filter area. The filter media consists of a sintered steel fiber mat using 2 {mu}m diameter fibers. We conducted an optimization study for filter efficiency and pressure drop to determine the filter design parameters of pleat width, pleat depth, outside diameter of the cylinder, and the total number of cylinders. Several prototype cylinders were then built and evaluated in terms of filter cleaning by reverse air pulses. The results of these studies were used to build the high efficiency steel filter. We evaluated the prototype filter for efficiency and cleanability. The DOP filter certification test showed the filter has a passing efficiency of 99.99% but a failing pressure drop of 0.80 kPa at 1,700 m{sup 3}/hr. Since we were not able to achieve a pressure drop less than 0.25 kPa, the steel filter does not meet all the criteria for a HEPA filter. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned by reverse air pulses. The next phase of the prototype evaluation consisted of installing the unit and support housing in the exhaust duct work of a uranium grit blaster for a field evaluation at the Y-12 Plant in Oak Ridge, TN. The grit blaster is used to clean the surface of uranium parts and generates a cloud of UO{sub 2} aerosols. We used a 1,700 m{sup 3}/hr slip stream from the 10,200 m{sup 3}/hr exhaust system.
- Research Organization:
- Lawrence Livermore National Lab., CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 10135974
- Report Number(s):
- UCRL-JC-109769; CONF-920823-8; ON: DE93008024
- Resource Relation:
- Conference: 22. Department of Energy (DOE)/Nuclear Regulatory Commission (NRC) nuclear air cleaning and treatment conference,Denver, CO (United States),24-27 Aug 1992; Other Information: PBD: Jan 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Preliminary field evaluation of high efficiency steel filters
Preliminary field evaluation of high efficiency steel filters
Related Subjects
42 ENGINEERING
AIR FILTERS
EVALUATION
URANIUM OXIDES
REMOVAL
STAINLESS STEELS
CLEANING
FUNCTIONAL MODELS
EFFICIENCY
PRESSURE DROP
PULSES
DUCTS
AEROSOLS
COST
ECONOMIC ANALYSIS
PERFORMANCE TESTING
AIR POLLUTION CONTROL
540120
420200
CHEMICALS MONITORING AND TRANSPORT
FACILITIES, EQUIPMENT, AND TECHNIQUES