Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

EP-toxicity testing of mercury removal resin grout

Technical Report ·
DOI:https://doi.org/10.2172/10134984· OSTI ID:10134984

To determine which category a waste will fit into, the EPA requires a classification test. The test, EP-toxicity, consists of a physical integrity test followed by an extraction. For the case of the mercury removal resin grout, the mercury concentration in the extract cannot exceed 0.2 mg/L if the waste is to be classified as ``solid waste.`` Otherwise, the waste is classified as ``hazardous.`` Simulated process solutions were used to load the mercury removal resin. The resin was solidified with the addition of cement and water using a formulation based on grout formulations typically used to solidify power reactor ion exchange resins. Envirodyne Engineers of St. Louis, Missouri, an EPA sanctioned laboratory, performed the EP-toxicity test for the two samples. One sample was a blank which was made with unloaded resin. For the formulation tested, the EP-toxicity test results showed that the mercury removal resin grout does not fit into the ``hazardous waste`` category.

Research Organization:
Du Pont de Nemours (E.I.) and Co., Aiken, SC (United States). Savannah River Lab.
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-76SR00001; AC09-89SR18035
OSTI ID:
10134984
Report Number(s):
DPST--84-557; ON: DE92010991
Country of Publication:
United States
Language:
English