R&D ERL: G5 test and commissioning plan

Technical Report ·
DOI:https://doi.org/10.2172/1013464· OSTI ID:1013464

Gun-to-5-cell cavity (G5) setup (Fig 1-2) can be considered as the first stage of the final BNL ERL design. The goal of the G5 setup is to test critical ERL components with the beam and characterize the beam produced by the gun. Also, this test will be used to assess effectiveness of the zigzag merger, which will be installed later in the ERL setup. The major components under the test will include the SRF gun, the five-cell SRF cavity, vacuum components, parts of the control and diagnostic systems. G5 is designed to measure the following beam parameters: (1) projected bunch emittance (?) and Twiss parameters ({alpha}, {beta}); (2) slice emittance; (3) bunch length; and (4) longitudinal and transverse halo.

Research Organization:
Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider
Sponsoring Organization:
DOE - Office Of Science
DOE Contract Number:
AC02-98CH10886
OSTI ID:
1013464
Report Number(s):
BNL--91048-2010-IR; KB0202011
Country of Publication:
United States
Language:
English

Similar Records

ERL R&D: G5 test and Commissioning Plan
Technical Report · Sun Jan 31 23:00:00 EST 2010 · OSTI ID:1061967

MERGER SYSTEM OPTIMIZATION IN BNL HIGH CURRENT R&D ERL
Conference · Mon Jun 25 00:00:00 EDT 2007 · OSTI ID:910386

R&D ERL: Diagnostics