Engineering task plan for the vapor monitor installation into 241-C-103 tank
A vapor flow monitor is to be installed into the 241-C-103 tank`s exhaust, just downstream of the HEPA filter. The flow monitor system includes the flow sensor, the baffle assembly, the signal conditioning and control electronics, and a chart recorder. The electronics package and the chart recorder are installed into a small, heated instrument cabinet that is mounted on the same steel pallet on which the flowmeter and the diffuser assembly is mounted. The flowmeter is connected to the HEPA filter with an unheated, un-insulated flex hose. An automatic drain, upstream of the flowmeter, is designed to automatically drain the condensate into an evaporating pan. The flowmeter is heated with a temperature controlled heater to avoid condensation.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10117709
- Report Number(s):
- WHC-SD-WM-ETP-107; ON: DE95006895; TRN: 95:001812
- Resource Relation:
- Other Information: PBD: Dec 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Acceptance/operational test procedure 241-AN-107 Video Camera System
Engineering task plan for Tanks 241-AN-103, 104, 105 color video camera systems
Related Subjects
42 ENGINEERING
TANKS
VENTILATION
GASEOUS WASTES
HANFORD RESERVATION
RADIOACTIVE WASTE STORAGE
FLOWMETERS
INSTALLATION
SIGNAL CONDITIONING
UNDERGROUND STORAGE
FLOW RATE
VAPORS
052002
420200
WASTE DISPOSAL AND STORAGE
FACILITIES, EQUIPMENT, AND TECHNIQUES