Dosimetry quality assurance in Martin Marietta Energy Systems` centralized external dosimetry system
Conference
·
OSTI ID:10116719
External dosimetry needs at the four Martin Marietta Energy Systems facilities are served by Energy Systems Centralized External Dosimetry System (CEDS). The CEDS is a four plant program with four dosimeter distribution centers and two dosimeter processing centers. Each plant has its own distribution center, while processing centers are located at ORNL and the Y-12 Plant. The program has been granted accreditation by the Department of Energy Laboratory Accreditation Program (DOELAP). The CEDS is a TLD based system which is responsible for whole-body beta-gamma, neutron, and extremity monitoring. Beta-gamma monitoring is performed using the Harshaw/Solon Technologies model 8805 dosimeter. Effective October 1, 1992 the standard silver mylar has been replaced with an Avery mylar foil blackened on the underside with ink. This was done in an effort to reduce the number of light induced suspect readings. At this time we have little operational experience with the new blackened mylars-The CEDS neutron dosimeter is the Harshaw model 8806B. This card/holder configuration contains two TLD-600/TLD-700 chip pairs; one pair is located beneath a cadmium filter and one pair is located beneath a plastic filter. In routine personnel monitoring the CEDS neutron dosimeter is always paired with a CEDS beta-gamma dosimeter.The CEDS extremity dosimeter is composed of a Harshaw thin TLD-700 dosiclip placed inside a Teledyne RB-4 finger sachet. The finger sachet provides approximately 7 mg/cm{sup 2} filtration over the chip. A teflon ring surrounds the dosiclip to help prevent tearing of the vinyl sachet.
- Research Organization:
- Oak Ridge Y-12 Plant, TN (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC05-84OS21400
- OSTI ID:
- 10116719
- Report Number(s):
- Y/DQ--32; CONF-9211124--5; ON: DE93004757
- Country of Publication:
- United States
- Language:
- English
Similar Records
Dosimetry quality assurance in Martin Marietta Energy Systems' centralized external dosimetry system
An investigation of false positive dosimetry results
The Department of Energy Laboratory Accreditation Program in personnel dosimetry: Results of the pilot performance test
Conference
·
Fri Oct 23 00:00:00 EDT 1992
·
OSTI ID:6892650
An investigation of false positive dosimetry results
Technical Report
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:515496
The Department of Energy Laboratory Accreditation Program in personnel dosimetry: Results of the pilot performance test
Technical Report
·
Wed Oct 01 00:00:00 EDT 1986
·
OSTI ID:6986939
Related Subjects
054000
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
560151
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
EXTERNAL IRRADIATION
HEALTH AND SAFETY
MAN
ORGDP
ORNL
PADUCAH PLANT
PERSONNEL
QUALITY CONTROL
RADIATION PROTECTION
THERMOLUMINESCENT DOSEMETERS
Y-12 PLANT
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
560151
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
EXTERNAL IRRADIATION
HEALTH AND SAFETY
MAN
ORGDP
ORNL
PADUCAH PLANT
PERSONNEL
QUALITY CONTROL
RADIATION PROTECTION
THERMOLUMINESCENT DOSEMETERS
Y-12 PLANT