Verification of the MAXIGASP and POPGASP Computer Codes for Environmental Dose Assessment
MAXIGASP and POPGASP are environmental dosimetry codes that are based on the NRC dispersion module, XOQDOQ, and the NRC dosimetry module, GASPAR. XOQDOQ and GASPAR have been verified previously. The four remaining modules of MAXIGASP and POPGASP control input/output functions and data transfer. The results of MAXIGASP and POPGASP have been verified by comparison of hand calculated doses with program input.