Design and performance of the SLD Vertex Detector, a 120 Mpixel tracking system
Conference
·
OSTI ID:10114911
- Brunel Univ., Uxbridge (United Kingdom)
- Rutherford Appleton Lab., Chilton (United Kingdom); and others
This paper describes the design, construction, and initial operation of the SLD Vertex Detector, the first device to employ charge coupled devices (CCDs) on a large scale in a high energy physics experiment. The Vertex Detector comprises 480 CCDs, with a total of 120 Mpixels. Each pixel functions as an independent particle detecting element, providing space point measurements of charged particle tracks with a typical precision of 5 {mu}m in each co-ordinate. The CCDs are arranged in four concentric cylinders just outside the beam pipe which surrounds the e{sup +}e{sup {minus}} collision point of the SLAC Linear Collider (SLC). The Vertex Detector is a powerful tool for distinguishing secondary vertex tracks, produced by decay in flight of heavy flavour hadrons or tau leptons, from tracks produced at the primary event vertex. Because the colliding beam environment imposes severe constraints on the design of such a detector, a six year R&D programme was needed to develop solutions to a number of problems. The requirements include a low-mass structure (to minimise multiple scattering) both for mechanical support and to provide signal paths for the CCDS; operation at low temperature with a high degree of mechanical stability; and relatively high speed CCD readout, signal processing, and data sparsification. The lessons learned through the long R&D period should be useful for the construction of large arrays of CCDs or smart pixel devices in the future, in a number of areas of science and technology.
- Research Organization:
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 10114911
- Report Number(s):
- SLAC-PUB--5906; CONF-920837--46; ON: DE94005241; IN: SLD-NOTE-217
- Country of Publication:
- United States
- Language:
- English
Similar Records
VXD3: The SLD vertex detector upgrade based on a 307 Mpixel CCD system
VXD3: The SLD vertex detector upgrade based on a 307 Mpixel CCD system
VXD3: The SLD vertex detector upgrade based on a 307 MPixel CCD system
Conference
·
Sat Jul 01 00:00:00 EDT 1995
·
OSTI ID:382977
VXD3: The SLD vertex detector upgrade based on a 307 Mpixel CCD system
Conference
·
Sat Jul 01 00:00:00 EDT 1995
·
OSTI ID:135522
VXD3: The SLD vertex detector upgrade based on a 307 MPixel CCD system
Conference
·
Thu Nov 30 23:00:00 EST 1995
·
OSTI ID:161567