Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Guiding hard x rays with glass polycapillary fiber

Conference ·
OSTI ID:10114030
; ; ;  [1]; ;  [2]
  1. X-Ray Optical Systems, Inc., Albany, NY (United States)
  2. Brookhaven National Lab., Upton, NY (United States)
X rays can be guided through a polycapillary fiber by multiple total reflections from the smooth channel walls of the fiber. Using monochromatic Synchrotron Radiation at energies of 22 and 44 keV, we measured the efficiency of transmission of x rays through polycapillary fibers with channel diameters of about 13 {mu}m. Efficiencies of 57.3% and 54.5% for 22 keV and 44 keV x rays, respectively, were obtained with a 120-mm-long straight polycapillary fiber aligned with the incident beam. These values are close to the open fraction of the fiber, which is about 60%. In addition, transmission efficiency was measured as a function of the tilt angle between the incident beam and the axis of the fiber. We also measured the transmission efficiency as a function of the deflection angle for a 114-mm-long curved polycapillary fiber. The measurements are compared with a ray-tracing simulation.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016; FG02-91ER81221
OSTI ID:
10114030
Report Number(s):
BNL--49773; CONF-930824--31; ON: DE94004949; BR: KM0000000
Country of Publication:
United States
Language:
English