We report on an option study of two potential x-ray systems for orthogonal radiography at Area C in the LANSCE facility at Los Alamos National Laboratory. The systems assessed are expected to be near equivalent systems to the presently existing Cygnus capability at the Nevada Test Site. Nominal dose and radiographic resolution of 4 rad (measured at one meter) and 1 mm spot are desired. Both a system study and qualitative design are presented as well as estimated cost and schedule. Each x-ray system analyzed is designed to drive a rod-pinch electron beam diode capable of producing the nominal dose and spot.