Transient radiation-induced absorption in laser materials

Conference ·
OSTI ID:10107154
Transient radiation-induced absorption losses in laser materials have been measured using a pulsed nuclear reactor. Reactor pulse widths of 70 to 90 {mu}s and absorbed doses of 1 to 7.5 krad have been used. Transmission recovery times and peak absorption coefficients are given. Materials tested include LiNbO{sub 3}, GSGG, silica substrates, and filter glasses used in the laser cavity. The filter glasses are tested at discrete wavelengths in the range 440--750 nm. Lithium niobate , MgO doped LiNbO{sub 3}, GSGG, and the silica substrates are tested at 1061 nm.
Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
10107154
Report Number(s):
SAND--93-0579C; CONF-940142--1; ON: DE94003773; BR: GB0103012
Country of Publication:
United States
Language:
English

Similar Records

Transient radiation-induced absorption in the materials for a GSGG laser
Technical Report · Sun Oct 31 23:00:00 EST 1993 · OSTI ID:10115362

Transient radiation-induced absorption at 1061 nm in LiNiO[sub 3] and MgO:LiNbO[sub 3]
Journal Article · Wed Jun 01 00:00:00 EDT 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:7028247

Transient radiation-induced absorption in materials for the DOI laser