Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Interlaboratory comparison of the horizontal pipe insulation test apparatus up to 350{degrees}C

Conference ·
OSTI ID:10105746
 [1];  [2];  [3];  [4]
  1. Pabco, Fruita, CO (United States)
  2. Oak Ridge National Lab., TN (United States)
  3. McElroy (David L.), Knoxville, TN (United States)
  4. National Institute of Standards and Technology, Boulder, CO (United States)
The purpose of this interlaboratory comparison was to provide information for the precision and bias section in the ASTM Standard Test Method C 335, {open_quotes}Steady-State Heat Transfer Properties of Horizontal Pipe Insulation.{close_quotes} (The text describes the ASTM C 335 test method, the specimens tested and the test protocol). The apparent thermal conductivity of two rigid calcium silicate pipe insulation specimens was measured by eight laboratories. Each laboratory measured both specimens at four different temperatures. The test mean temperatures ranged from 35 to 390{degrees}C. The two standard deviation value for the data ranged from 4.5 to 7.7% and the average value was 6.3%. The statement recommended for the precision and bias statement for Section 13.1.4 of ASTM C 335 is: {open_quotes}Tests performed at seven different laboratories using guarded-end horizontal pipe test apparatus and at one laboratory using an unguarded cylindrical screen test apparatus on two specimens of calcium silicate insulation in the range of mean temperatures from 35 to 390{degree}C did not vary by more than 6.3% (two standard deviations) of the average.{close_quotes}
Research Organization:
Oak Ridge National Lab., TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
10105746
Report Number(s):
CONF-9311131--1; ON: DE94003498
Country of Publication:
United States
Language:
English

Similar Records

Interlaboratory comparison of the ASTM C 335 pipe insulation test
Conference · Sat Dec 31 23:00:00 EST 1977 · Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States) · OSTI ID:6240996

Evaluation of high-temperature pipe insulations using a 16-in. -diameter pipe test apparatus
Conference · Sat Dec 31 23:00:00 EST 1977 · Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States) · OSTI ID:6384708

Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes]
Journal Article · Wed Apr 18 20:00:00 EDT 2018 · International Journal of Applied Ceramic Technology · OSTI ID:1440835