Results from the Soudan 2 detector

Conference ·
OSTI ID:10103598
The Soudan 2 underground detector is a large fine-grained tracking calorimeter comprised of long drift tubes read out by proportional wires. It is surrounded by a proportional tube shield. Preliminary nucleon decay results with 0.5 fiducial kT-yr exposure give 90% CL lower limits of {tau}/B > 4.5 {times} 10{sup 30}yr for the mode p {yields} K{sup +}{nu}. A search for GUT magnetic monopoles making highly ionizing tracks yielded a 90% CL upper flux limit of 8.7 {times} 10{sup {minus}15} cm{sup {minus}2}s{sup {minus}1}sr{sup {minus}1} for monopole velocities of {beta} > 2 {times} 10{sup {minus}3} in data taken over almost three years.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
10103598
Report Number(s):
ANL-HEP-CP--92-85; CONF-920837--8; ON: DE93002777; IN: PDK-531
Country of Publication:
United States
Language:
English

Similar Records

Results from the Soudan 2 detector
Conference · Tue Dec 31 23:00:00 EST 1991 · OSTI ID:6936479

Results from the Soudan 2 detector
Conference · Tue Feb 04 23:00:00 EST 1992 · AIP Conference Proceedings (American Institute of Physics); (United States) · OSTI ID:5015984

Search for magnetic monopoles with the Soudan 2 detector