The GlueX central drift chamber: Design and performance
Journal Article
·
· Nuclear Instruments and Methods A
Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC05-06OR23177
- OSTI ID:
- 1008172
- Report Number(s):
- JLAB-PHY-10-1314; DOE/OR/23177-1488; TRN: US201106%%317
- Journal Information:
- Nuclear Instruments and Methods A, Vol. 622, Issue 1; ISSN 0168-9002
- Country of Publication:
- United States
- Language:
- English
Similar Records
Control and Calibration of GlueX Central Drift Chamber Using Gaussian Process Regression
The GlueX Forward Drift Chambers
Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment
Conference
·
Thu Dec 01 00:00:00 EST 2022
·
OSTI ID:1008172
+3 more
The GlueX Forward Drift Chambers
Conference
·
Wed Oct 01 00:00:00 EDT 2008
·
OSTI ID:1008172
Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment
Journal Article
·
Fri Jul 01 00:00:00 EDT 2016
· Instruments and Experimental Techniques
·
OSTI ID:1008172
+1 more