Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS
Journal Article
·
· J. Synchrotron Rad.
- IIT
There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.
- Research Organization:
- Advanced Photon Source (APS), Argonne National Laboratory (ANL), Argonne, IL (US)
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 1002506
- Journal Information:
- J. Synchrotron Rad., Journal Name: J. Synchrotron Rad. Journal Issue: (4) ; 07, 2010 Vol. 17; ISSN 0909-0495; ISSN JSYRES
- Country of Publication:
- United States
- Language:
- ENGLISH
Similar Records
The BioCAT Microprobe for X-Ray Fluorescence Imaging, MicroXAFS and Microdiffraction Studies on Biological Samples
Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source
High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam
Conference
·
Tue Jul 31 00:00:00 EDT 2007
·
OSTI ID:1008978
Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source
Journal Article
·
Tue Jun 05 00:00:00 EDT 2012
· AIP Conference Proceedings
·
OSTI ID:22004103
High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam
Journal Article
·
Wed Jan 14 23:00:00 EST 2009
· J. Synchrotron Rad.
·
OSTI ID:1005443