Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

1-to 10-keV x-ray backlighting of annular wire arrays on the Sandia Z-machine using bent-crystal imaging techniques.

Conference ·
OSTI ID:1002113

Annular wire array implosions on the Sandia Z-machine can produce >200 TW and 1-2 MJ of soft x rays in the 0.1-10 keV range. The x-ray flux and debris in this environment present significant challenges for radiographic diagnostics. X-ray backlighting diagnostics at 1865 and 6181 eV using spherically-bent crystals have been fielded on the Z-machine, each with a {approx}0.6 eVspectral bandpass, 10 {micro}m spatial resolution, and a 4 mm by 20mm field of view. The Z-Beamlet laser, a 2-TW, 2-kJ Nd:glass laser({lambda} = 527 nm), is used to produce 0.1-1 J x-ray sources for radiography. The design, calibration, and performance of these diagnostics is presented.

Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1002113
Report Number(s):
SAND2003-2625C
Country of Publication:
United States
Language:
English

Similar Records

A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility
Journal Article · Tue Oct 10 00:00:00 EDT 2017 · Review of Scientific Instruments · OSTI ID:1441469

Monochromatic x-ray imaging experiments on the Sandia National Laboratories Z facility (invited)
Journal Article · Fri Oct 01 00:00:00 EDT 2004 · Review of Scientific Instruments · OSTI ID:20636717

Enhancement of x-ray yield from the Z-Beamlet laser for monochromatic backlighting by using a prepulse
Journal Article · Sun Oct 15 00:00:00 EDT 2006 · Review of Scientific Instruments · OSTI ID:20861189