Magnetic pick-up coils and single turn flux loops are installed on the FRX-L device. The combination of the two measurements provides the excluded flux radius that approximates the separatrix radius of the field-reversed configuration plasma. Arrays of similar probes are used to map out local magnetic field dynamics beyond both ends of the theta-coil confinement region to help understand the effects of cusp locations on flux trapping during the FRC formation process. Details on the probe design and system calibrations are presented. The overall system calibration of excluded flux radius measurement is examined by replacing FRC plasma with a known radius aluminum conductor cylinder.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE
OSTI ID:
977553
Report Number(s):
LA-UR-04-2566; TRN: US1002944
Resource Relation:
Journal Volume: 75; Journal Issue: 10; Conference: Submitted to: 15th topical conference on high-temperature plasma diagnostics, 19-22 April 2004, San Diego, California
Country of Publication:
United States
Language:
English