In July, 2000, the Controlled Materials Accountability and Tracking System (COMATS) Team, with the assistance of a representative of the Local Area Network Materials Accountability System (LANMAS) development team from Savannah River, performed an evaluation to enumerate and qualify differences between the current LANMAS functionality and LLNL requirements as implemented by COMATS. The differences found range from minor to serious deficiencies of LANMAS in relation to current LLNL MC&A practice. Therefore, we recommend a gradual integration of LANMAS into a hybrid system which uses LANMAS to satisfy DOE/NNSA MC&A and reporting requirements and uses COMATS to satisfy LLNL-specific MC&A and operational requirements.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE Office of Defense Programs (DP) (US)
DOE Contract Number:
W-7405-Eng-48
OSTI ID:
793695
Report Number(s):
UCRL-ID-140222; TRN: US200218%%43
Resource Relation:
Other Information: PBD: 25 Aug 2000