Title: Divertor E X B Plasma Convection in DIII-D

Conference ·
OSTI ID:766948

Extensive two-dimensional measurements of plasma potential in the DIII-D tokamak divertor region are reported for standard (ion VB{sub T} drift toward divertor X-point) and reversed B{sub T} directions; for low (L) and high (H) confinement modes; and for partially detached divertor mode. The data are consistent with recent computational modeling identifying E x B{sub T} circulation, due to potentials sustained by plasma gradients, as the main cause of divertor plasma sensitivity to B{sub T} direction.

Research Organization:
General Atomics, San Diego, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC03-99ER54463; W-7405-ENG-48; AC05-96OR22464; AC04-94AL85000; FG03-95ER54294
OSTI ID:
766948
Report Number(s):
GA-A23159; TRN: US0110522
Resource Relation:
Conference: 26th European Physical Society Conference on Controlled Fusion and Plasma Physics, Maastricht (NL), 06/14/1999--06/18/1999; Other Information: PBD: 1 Jul 1999
Country of Publication:
United States
Language:
English