Two one-segment core samples from tank 241-U-203 (U-203) were received by the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. In addition to the safety screening requirements, inductively coupled plasma (ICP) spectrographic analysis for lithium was performed to determine the extent of hydrostatic head fluid contamination during the sampling event. No notification limits were exceeded for these analyses.