Title: Mitigation of thermal transients by tube bundle inlet plenum design. [LMFBR]

Conference ·
OSTI ID:6837083

A multiphase program aimed at investigating the importance of thermal buoyancy to LMFBR steam-generator and heat-exchanger thermal hydraulics under low-flow transient conditions is being conducted in the Argonne Mixing Components Test Facility (MCTF) on a 60/sup 0/ sector shell-side flow model of the Westinghouse straight-tube steam generator being developed under the US/DOE large-component development program. A series of shell-side constant-flow thermal-downramp transient tests have been conducted focusing on the phenomenon of thermal-buoyancy-induced-flow channeling. In addition, it was discovered that a shell-inlet flow-distribution plenum can play a significant role in mitigating the severity of a thermal transient entering a steam generator or heat exchanger.

Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
6837083
Report Number(s):
CONF-840614-21; ON: DE84006406
Resource Relation:
Conference: Annual meeting of the American Nuclear Society, New Orleans, LA, USA, 3 Jun 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English