skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Main-coolant-pump shaft-seal reliability investigation. Interim report

Technical Report ·
DOI:https://doi.org/10.2172/6675354· OSTI ID:6675354

This report contains the results of a survey of reactor coolant pump shaft seal reliability. The survey sample is representatively large (approx. = 27% of total US commercial plant population) and includes the three industry seal suppliers (Bingham-Williamette, Byron Jackson, and Westinghouse). Operationally incurred/induced problems and seal redesign parameters are identified. Failure hypotheses in the form of fault trees have been developed to describe the failure mechanisms. Recommendations are made for seal reliability improvement.

Research Organization:
Borg-Warner Corp., Carson, CA (USA). Byron Jackson Pump Div.
OSTI ID:
6675354
Report Number(s):
EPRI-NP-2611-Vol.1; ON: DE83900266
Country of Publication:
United States
Language:
English