Title: Baseline estimate of the retained gas volume in Tank 241-C-106

Technical Report ·
DOI:https://doi.org/10.2172/663404· OSTI ID:663404

This report presents the results of a study of the retained gas volume in Hanford Tank 241-C-106 (C-106) using the barometric pressure effect method. This estimate is required to establish the baseline conditions for sluicing the waste from C-106 into AY-102, scheduled to begin in the fall of 1998. The barometric pressure effect model is described, and the data reduction and detrending techniques are detailed. Based on the response of the waste level to the larger barometric pressure swings that occurred between October 27, 1997, and March 4, 1998, the best estimate and conservative (99% confidence) retained gas volumes in C-106 are 24 scm (840 scf) and 50 scm (1,770 scf), respectively. This is equivalent to average void fractions of 0.025 and 0.053, respectively.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
663404
Report Number(s):
PNNL-11890; R&D Project: 28165; ON: DE98054531; BR: 820201000; TRN: 99:000077
Resource Relation:
Other Information: PBD: Jun 1998