Title: Maximum credible event determination for the surveillance powder samples and their handling containers

Technical Report ·
DOI:https://doi.org/10.2172/6208092· OSTI ID:6208092

An investigation was done to determine the maximum credible event value for samples of explosives and disassembled components up to 1.2 g when stored in conductive plastic vials as packaged and handled, stored, or transported at Mound. The test was performed at Test Firing, with photographs taken before and after the test. The standard propagation test setup was used; a vial containing 1.2 g of PETN (pentaerythritol tetranitrate) was surrounded by other like vials containing 1.2-g samples of PETN. The 1.2-g PETN pellet was then ignited by an EX-12 detonator. The test showed that there was no propagation and that the maximum credible event value for the handling tray is 1.2 g. The test also showed that when the tray is placed in a metal container the MCE value will still be 1.2 g. 9 figs.

Research Organization:
EG and G Mound Applied Technologies, Miamisburg, OH (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-88DP43495
OSTI ID:
6208092
Report Number(s):
MLM-3704; ON: DE92001604
Country of Publication:
United States
Language:
English