The performance of the ambient air resistance temperature detectors (RTDs) just after the hydrogen burn in the TMI-2 Reactor Building is examined. The performance of the sensors is compared with physical models of the sensor/ambient air system. With one exception, the RTD data appear to be valid for the period examined. Based on the data, the hydrogen burn ended considerably before the first data points were recorded.

Research Organization:
EG and G Idaho, Inc., Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6138176
Report Number(s):
GEND-INF-030; ON: DE83011491
Resource Relation:
Other Information: Portions are illegible in microfiche products