A high-current, high-voltage power supply with special output current waveform for APS injector synchrotron dipole magnets
This paper describes a high-voltage, high-current power supply for the injector synchrotron dipole magnets at APS. In order to reset the dipole magnets in each cycle two different current waveforms are suggested. The first current waveform consists of three sections, namely: dc-reset, linear ramp, and recovery sections where injection is done on the fly''. The second current waveform consists of six different sections, dc-reset, transition to injection level, injection flat level, parabolic, linear ramp and recovery sections. The effect of such waveforms on the beam is discussed and the power supply limitations to follow such waveforms are given. The power supply limitations are due to the power components and control loops. The reference for the current loop is generated by a DAC which is discussed.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 6060977
- Report Number(s):
- ANL/CP-73788; CONF-911106-41; ON: DE92004132
- Resource Relation:
- Conference: IEEE nuclear science symposium, Santa Fe, NM (United States), 5-9 Nov 1991
- Country of Publication:
- United States
- Language:
- English
Similar Records
A high-current, high-voltage power supply with special output current waveform for APS injector synchrotron dipole magnets
Design and simulation of high accuracy power supplies for injector synchrotron dipole magnets
Related Subjects
MAGNETIC DIPOLES
POWER SUPPLIES
SYNCHROTRON RADIATION SOURCES
BEAM INJECTION
DIGITAL-TO-ANALOG CONVERTERS
MAGNETIC FIELDS
MAGNETS
WAVE FORMS
DIPOLES
ELECTRONIC EQUIPMENT
EQUIPMENT
MULTIPOLES
RADIATION SOURCES
430302* - Particle Accelerators- Injection & Extraction Systems
430303 - Particle Accelerators- Experimental Facilities & Equipment