Title: TRAC-PF1 post-test predictions for the Semiscale Natural-Circulation Tests S-NC-2 and S-NC-6. [PWR]

Conference ·
OSTI ID:5732515

The TRAC prediction are compared to the data for the Semiscale natural-circular Tests S-NC-2B and S-NC-6. S-NC-2B is a baseline test covering single- and two-phase natural circulation as well as reflux; here TRAC compares quite well with the experiment results for mass flow. For Test S-NC-6, which is a reflux test with various amounts of nitrogen injected into the system, the TRAC prediction of the reflux rate is close to the experiment value with no nitrogen in the system. Ultimately, the maximum reflux rate predicted by TRAC is about 20% higher than the data.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5732515
Report Number(s):
LA-UR-83-2806; CONF-830901-16; ON: DE84001031
Resource Relation:
Conference: Anticipated and abnormal plant transients in light water reactors conference, Jackson, WY, USA, 26 Sep 1983; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English