Commissioning of the APS real-time orbit feedback system
- Argonne National Lab., IL (United States). Advanced Photon Source
A unified global and local closed-orbit feedback system has been implemented at the Advanced Photon Source in order to stabilize both particle and photon beams. Beam stability requirements in the band up to 50 Hz are 17 {micro}m in the horizontal plane and 4.4 {micro}m vertically. Orbit feedback algorithms are implemented digitally using multiple digital signal processors, with computing power distributed in 20 VME crates around the storage ring. Each crate communicates with all others via a fast reflective memory network. The system has access to 320 rf beam position monitors together with x-ray beam position monitors in both insertion device and bending magnet beamlines. Up to 317 corrector magnets are available to the system. The global system reduces horizontal rms beam motion at the x-ray source points by more than a factor of two in the frequency band from 10 mHz to 50 Hz.
- Research Organization:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- USDOE Office of Energy Research, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 541886
- Report Number(s):
- ANL/ASD/CP-92234; CONF-970503-; ON: DE97053294; TRN: 98:008451
- Resource Relation:
- Conference: 17. IEEE particle accelerator conference, Vancouver (Canada), 12-16 May 1997; Other Information: PBD: [1997]
- Country of Publication:
- United States
- Language:
- English