Title: CSER-025: PFP storage of 9.25 inch tall, 4.4 kg Pu cans on existing vault four pedestals

Technical Report ·
DOI:https://doi.org/10.2172/327257· OSTI ID:327257

A nuclear criticality safety analysis has been performed to increase the approved plutonium mass limit for cans stored in Vault {number_sign}4 cubicles at PFP. The cubicles were approved to hold up to 2.5 kg of plutonium on each pedestal. The purpose of this CSER is to accommodate the storage of 4.4 kg of plutonium in PuO, (5.0 kg PuO,) in Vault {number_sign}4 cubicles. The highest k{sub eff} calculated for all possible scenarios is 0.868 + 0.003 when every other cubicle is left vacant, which is well below the criticality safety limit of k{sub eff}=0.935. Consequently, an increase of plutonium mass to 4.4 kg per can is within acceptable safety limits for this configuration.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
327257
Report Number(s):
HNF-SD-SQA-CSA-522; ON: DE98059572; BR: EW7003000; TRN: 97000097
Resource Relation:
Other Information: PBD: 6 Feb 1997
Country of Publication:
United States
Language:
English