Tokamak Physics EXperiment (TPX): Toroidal magnet design, development and manufacture. SDRL 31, Magnet sensors. Volume 4
- Babcock and Wilcox Co., Lynchburg, VA (United States)
The requirement for magnet sensors to verify the TF magnet system operation and aid in diagnostic assessment are defined. However, generally one does not specify such a system in the absence of a definition of the local I&C system. Also, one would expect that there would be great benefit (economy, redundancy, compatibility, etc.) in specifying common components for all of the magnet system. Thus specifying the sensors requirement we have tried to be flexible to accommodate future adjustments to these systems.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Babcock and Wilcox Co., Lynchburg, VA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 230560
- Report Number(s):
- UCRL-CR-121738-Vol.4; ON: DE96009591; CNN: Contract B235308
- Resource Relation:
- Other Information: DN: Engineering drawings for this project are identified as CAPE-3106. Inquiries may be directed to: Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; PBD: 18 Aug 1995
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 46, CPDR review package. Volume 6
Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 15, System design description. Volume 1
Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 21, Materials and processes selection. Volume 2
Technical Report
·
Fri Aug 18 00:00:00 EDT 1995
·
OSTI ID:230560
Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 15, System design description. Volume 1
Technical Report
·
Fri Sep 22 00:00:00 EDT 1995
·
OSTI ID:230560
Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 21, Materials and processes selection. Volume 2
Technical Report
·
Tue Aug 15 00:00:00 EDT 1995
·
OSTI ID:230560