Title: Novel tune diagnostics for the Tevatron

Conference ·
OSTI ID:15017195

In the Tevatron collider, protons and antiprotons share the same beam pipe. This poses a challenge in the measurement of tunes for both species simultaneously because of the possibility of signal contamination from the other species. The tune of each bunch is also very different because of beam-beam effects from parasitic crossing points. This means that the tune diagnostics must be able to differentiate between protons and anti-protons, it also has to measure tunes from each bunch. There are three different tune pickups used in the Tevatron: 1.7 GHz Schottky pickups, 21.4 MHz Schottky pickups and baseband pickups. These devices will be discussed in detail in this paper.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76CH03000
OSTI ID:
15017195
Report Number(s):
FERMILAB-CONF-05-086-AD; TRN: US200606%%400
Resource Relation:
Conference: To appear in the proceedings of Particle Accelerator Conference (PAC 05), Knoxville, Tennessee, 16-20 May 2005
Country of Publication:
United States
Language:
English