skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tevatron HTS power lead test

Conference ·
OSTI ID:15016935

Two pairs of ASC 6 kA power leads developed for the Tevatron were successfully tested at Fermilab at over-current conditions. Stable operation was achieved while operating at a current of 9.56 kA for five hours and while continuously ramping between 0-9.56 kA at a ramp rate of 200 A/s for one hour. The minimum required liquid nitrogen flow rate was measured to be 1.5 g/s at 10 kA. After ramping up to 10 kA at 200A/s, it took only 15 minutes to stabilize the upper copper section of the lead with a flow of 1.8 g/s of liquid nitrogen vapor. Testing under extreme operating conditions--270-370 kPa liquid nitrogen vapor pressure and over 0.1 T external magnetic field--demonstrated that the HTS part of the lead can safely operate in the current sharing mode and that this design has large operating margin.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76CH03000
OSTI ID:
15016935
Report Number(s):
FERMILAB-CONF-04-257-TD; TRN: US0503823
Resource Relation:
Conference: Prepared for Applied Superconductivity Conference: Harnessing the Magic (ASC 04), Jacksonville, Florida, 3-8 Oct 2004
Country of Publication:
United States
Language:
English

Similar Records

Thermal tests of 6 KA HTS current leads for the Tevatron
Conference · Thu Dec 09 00:00:00 EST 1999 · OSTI ID:15016935

HTS power leads for the BTEV interaction region
Conference · Sun May 01 00:00:00 EDT 2005 · OSTI ID:15016935

Tevatron higher energy testing
Technical Report · Sun Oct 01 00:00:00 EDT 1995 · OSTI ID:15016935