Eliminating the Spot Dilution Due to Kicker Switching in DARHT-II
Conference
·
OSTI ID:15003853
To produce four short x-ray pulses for radiography, the second-axis of the Dual Axis Radiographic Hydrodynamic Test facility (DARHT-II) will use a fast kicker to select current pulses out of the 2-ms duration beam provided by the accelerator. Beam motion during the kicker voltage switching could lead to dilution of the time integrated beam spot and make the spot elliptical. A large elliptical x-ray source produced by those beams would degrade the resolution and make radiographic analysis difficult. We have developed a tuning strategy to eliminate the spot size dilution, and tested the strategy successfully on ETA-II with the DARHT-II kicker hardware.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 15003853
- Report Number(s):
- UCRL-JC-151053; TRN: US1005091
- Resource Relation:
- Conference: Particle Accelertor Conference 2003, Portland, OR, May 12 - May 16, 2003
- Country of Publication:
- United States
- Language:
- English