Title: Compressed Air System Optimization Project Saves Energy and Improves Production at a Citation Forging Plant

Program Document ·
OSTI ID:1215933

In the 1990s, a subsidiary of the Citation Corporation, Interstate Forging, implemented a compressed air system improvement project at its Milwaukee, Wisconsin, forging plant. This improvement enabled the plant to maintain an adequate and stable pressure level using fewer compressors, which led to improved product quality and lower production downtime. The project also yielded annual energy savings of 820,000 kWh and $45,000. With a total project cost of $67,000, the plant achieved a simple payback of just 1.5 years.