skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Field quality improvements in superconducting magnets for RHIC

Conference ·
OSTI ID:10114067

A number of techniques have been developed-and tested to improve the field quality in the superconducting dipole and quadrupole magnets to be used in the Relativistic Heavy Ion Collider (RHIC). These include adjustment in the coil midplane gap to compensate for the allowed and non-allowed harmonics, inclusion of holes and cutouts in the iron yoke to reduce the so harmonics, and magnetic tuning shims to correct for the residual errors. We compare the measurements with the calculations to test the validity of these concepts.

Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
10114067
Report Number(s):
BNL-60352; CONF-940618-117; ON: DE95006096
Resource Relation:
Conference: EPAC 94 - 4. European particle accelerator conference,London (United Kingdom),27 Jun - 1 Jul 1994; Other Information: PBD: [1994]
Country of Publication:
United States
Language:
English