Determination of possible damage/degradation of the Sandia National Laboratories Personal Nuclear Accident Dosimeter (PNAD).
This report describes the results of an inspection performed on the existing stock of SNL Personal Nuclear Accident Dosimeters (PNADs). The current stock is approximately 20 years old, and has not been examined since their initial acceptance. A small random sample of PNADs were opened (a destructive process) and the contents visually examined. Sample contents were not degraded and indicate that the existing stock of SNL PNADs is acceptable for continued use.
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 933225
- Report Number(s):
- SAND2008-2971; TRN: US0803746
- Country of Publication:
- United States
- Language:
- English
Similar Records
Personal nuclear accident dosimetry at Sandia National Laboratories
Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.
Lawrence Livermore National Laboratory Plutonium Facility Personal Nuclear Accident Dosimeter
Technical Report
·
Sun Sep 01 00:00:00 EDT 1996
·
OSTI ID:933225
Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.
Technical Report
·
Thu Sep 01 00:00:00 EDT 2011
·
OSTI ID:933225
Lawrence Livermore National Laboratory Plutonium Facility Personal Nuclear Accident Dosimeter
Conference
·
·
OSTI ID:933225
+3 more