Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.
This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20-23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1029804
- Report Number(s):
- SAND2011-6416; TRN: US1200047
- Country of Publication:
- United States
- Language:
- English
Similar Records
PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise
Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010
Results from 2010 Caliban Criticality Dosimetry Intercomparison
Technical Report
·
Fri Oct 28 00:00:00 EDT 2011
·
OSTI ID:1029804
Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010
Technical Report
·
Tue Jun 21 00:00:00 EDT 2011
·
OSTI ID:1029804
+5 more
Results from 2010 Caliban Criticality Dosimetry Intercomparison
Technical Report
·
Wed Oct 12 00:00:00 EDT 2011
·
OSTI ID:1029804